Product Introduction :
It is composed of three series 9988/818/TH freely, which is easy to realize the function of "what you see is what you get". Different combinations of various materials are suitable for most measurement conditions of pure liquid flow. Precise debugging before leaving the factory ensures the accuracy of the flow measurement as much as possible. Get more accurate flow measurement with minimal installation man-hours and minimal commissioning time available in the field.
Features:
1: Suitable for measuring pure liquid flow;
2: Applicable flow velocity range: 0.3-6m/s;
3: Applicable pipeline size range: DN15-DN50 (1/2-2");
4: Materials with broad chemical resistance;
5: Only the paddle-wheel and the shaft are moving parts, and the replacement steps are simple and fast;
6: One-piece delivery, saving on-site installation/commissioning time;
7: Precise calibration before leaving the factory to ensure accurate flow measurement;
Applications:
1: Chemical production process measurement; 2: Pure water preparation system;
3: Water monitoring;
4: Central air conditioning cooling cycle system
5: Electronic photovoltaic cleaning system
6: Metallurgical industry
7: Electricity, chlor-alkali industry
Pressure/Temperature Graph:
Pressure/Temperature Rating:
(1)PPH body material Maximum 2 bar@90ºC, Maximum 15 bar@20ºC
(2)PVDF body material Maximum 2 bar@100ºC, Maximum 15 bar@20ºC
(3)PFA body material Maximum 2.2 bar@110ºC, Maximum 16.5 bar@20ºC
Channel input |
|
Single channel integrated paddle-wheel flowmeter |
Signal input type |
Digital signal |
RS485 MODBUS RTU communication protocol signal |
Frequency signal |
Range, 1-1500Hz |
Current signal |
Range, 4-20mA |
Measurement parameters |
|
Flow |
Shell material |
PBT |
Display Screen |
Shatterproof glass |
Keyboard |
4 keys, membrane keys, injection molded silicone rubber seal |
Display |
LCD display, automatic backlight |
Refresh rate |
1 second |
Indication |
Bar graph , open collector output, LED indicators for relay and alarm/error indication |
Mounting |
Cabinet mounting |
Mounting hole opening size 92x92mm,appearance size of the instrument 99x99mm |
|
On-site mounting |
Equipped with corresponding connector to combine with sensor |
|
Wall mounting |
Equipped with the corresponding installation box |
Ambient temperature |
|
-10-70ºC |
Storage temperature |
|
-15-85ºC |
LCD operating temperature |
-10-70ºC |
IP level |
Panel of cabinet-mounted version is IP65, the whole of On-site mounted version is IP65 |
Terminal block |
Shrapnel Press Terminal 28-12AWG |
Supply voltage |
12-24V DC ±10% voltage regulation (power input with anti-reverse connection protection) |
Supply voltage of sensor |
12-24V DC ±10% voltage regulation |
Open collector output |
50mA DC |
Relay power |
30V DC 1A two groups |
Relay power |
400 pulses/min |
Maximum pulse rate |
0.1-3200S |
Proportional pulse width |
0.1-320S |
Output current |
4-20mA, passive, full scale adjustable and reverse output |
Zero point |
The factory setting is 4.0mA, and the user can fine-tune it at 3.8-5.0mA |
Full point |
The factory setting is 20.0mA, and the user can fine-tune it at 19.0-21.0mA |
Precision |
Maximum error value±32uA@25ºC@24V DC |
Resolution |
6uA |
Refresh rate |
100mS |
Current terminal for receiving sensor |
4-20mA,the receiving terminal does not provide external voltage |